Install Fiber Optic Cable Pass-Thru Kit for SCC1 (Single-Carrier) Cabinets
Administering PNC Duplication
Administering PNC Duplication
Return to Task List
The license file enables PNC Duplication. If PNC Duplication is enabled on the System-Parameters
Customer-Options form, the following administration forms change:
•
Cabinet form
B-PNC sides of the CSS. The B-PNC is the duplicated hardware for the A-PNC. Either the A-
PNC or the B-PNC can provide full customized service. B-PNC cannot be used in a simplex PNC
configuration. Pairing of switch nodes is also defined here.
•
Fiber Link form
side of the CSS. If an endpoint on the A-PNC side is administered as an SNI, its corresponding
endpoint on the B-PNC side is determined (if switch nodes are paired in the cabinet form prior to
this administration) and displayed. However, administration of the duplicate B-PNC link is not
enforced until duplication is in full operation.
•
Duplication-Related System-Parameters form
of PNC duplication.
Return to Task List
Administering Fiber Links
Return to Task List
Additional fields appear on the
administration of fiber links on the B-PNC side of the CSS. If an endpoint on the A-PNC side is
administered as an SNI, its corresponding endpoint on the B-PNC side is determined (if switch nodes are
paired in the cabinet form prior to this administration) and displayed. However, administration of the
duplicate B-PNC link is not enforced until duplication is in full operation.
The following fields appear for basic fiber link administration:
•
Fiber Link #
uniquely identify a switch connection in the system and its duplicate if appropriate.
•
Board Location
SNI or EI board that is the first endpoint of the fiber link.
•
Board Type
•
Board Location
SNI or EI board that is the second endpoint of the fiber link.
•
Board Type
•
Is one endpoint remoted via a DS1 Converter Complex?
Converter complex is used to remote one endpoint. If a y is entered, A-PNC DS1 Converter
circuit pack Location must be administered on Page 1. A-PNC DS1 Converter circuit pack Type
displays. A-PNC DS1 Converter (DS1CONV) Attributes must be administered on Page 2 of this
form.
212
—
Additional fields appear to allow administration of switch nodes to A-PNC and
—
Additional fields appear to allow administration of fiber links on the B-PNC
Figure 39, Fiber Link Administration form,
—
Display-only field. From the command line, enter a 1- to 3-digit number to
—
Enter the cabinet, carrier, and slot that identifies the physical location of an
—
Display-only field showing the type of circuit pack in Endpoint-1.
—
Enter the cabinet, carrier, and slot that identifies the physical location of an
—
Display-only field showing the type of circuit pack in Endpoint-2.
—
An additional field appears to enable operation
on page 213 to allow
—
Enter y to specify that a DS1
SI Installation and Upgrades