Special Administration Requirements
Duplicated si systems, release 7.1 or later, must have the SPE Interchange field set correctly, or the
system will sometimes generate packet alarms that will prevent ISDN from working properly.
Type
change system-parameters maintenance
PARAMETERS form and verify that the SPE Interchange field is set to daily.
display system-parameters maintenance
OPERATIONS SUPPORT PARAMETERS
Product Identification: 1020000942
First OSS Telephone Number: 18004513036
Second OSS Telephone Number:
Alarm Origination to OSS Numbers: first-only
Cleared Alarm Notification? n
Restart Notification? y
Test Remote Access Port? y
CPE Alarm Activation Level: minor
Customer Access to INADS Port? y
Repeat Dial Interval (mins): 7
SCHEDULED MAINTENANCE
Daily Maintenance: daily
Control Channel Interchange: no
SPE Interchange: daily
Minimum required hardware
You need the following minimum required hardware to upgrade to Avaya Communication Manager.
Equipment
Basic si processor cabinet (SCC)
or
Basic si processor carrier (MCC)
Duplex processor cabinet (SCC)
or
Duplex processor carrier (MCC)
AC Power unit
TDM/LAN bus terminator (SCC) Need 2
SI Installation and Upgrades
June 2004
MAINTENANCE-RELATED SYSTEM PARAMETERS
Start Time: 05 : 00
System Clocks Interchange: no
Upgrades to Avaya Commnication Manager Made Easy
to display the MAINTENANCE-RELATED SYSTEM
Abbrev Alarm Report? y
Abbrev Alarm Report? n
Suspension Threshold: 5
Stop Time: 06 : 00
Save Translation: daily
Command Time-out (hours): 2
EXP-LINK Interchange: no
Notes
Contains the following circuit packs:
•
TN780 or TN2182 tone clock
•
TN2404 processor, Vintage 3 or
higher
•
TN792 duplicate interface (opt)
•
TN2401 NetCtrl/PktIntf
Contains the following circuit packs:
•
TN780 TN2182 tone clock
•
TN2404 processor, Vintage 3 or
higher
•
TN792 duplicate interface
•
TN2401 NetCtrl/PktIntf