Reference - Avaya MCC1 Installation And Upgrades

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

System 75 Small-Cabinet to R8si (Blowback)
Task List: System 75 Small Cabinet to R8si
1
Get the DOSS order number of the upgrade from the project manager and ask the regional
Customer Software Administration to administer customer options. See the
page
for telephone numbers.
2
Log in to the switch and respond to the Access Security Gateway (ASG) challenge.
3
For duplicated systems, verify that the switches are in auto: Type
Enter.
Verify that conditions are normal (this can take as long as 5 to 10 minutes). If the system refuses
to go onto a normal condition, refer to the maintenance procedures; if that fails, escalate the
problem.
4
If it is necessary to change the offer, type
Enter.
5
If changing offers and the Activate Offer field is n, set it to y and press Tab. A warning
message lets you know whether you need to save translations and reboot to make the change
permanent.
6
Press Enter to effect the changes or Cancel if there were no changes.
7
Type
change system-parameters customer-options
options that were purchased. Change the G3 version: field to V9.
Use these forms to verify the customer options are set correctly.
8
If the customer was using Supplementary Services Protocol b or d on an ISDN-PRI trunk group
before the upgrade, set the Basic Call Setup field on the QSIG Optional Features page to
.
y
9
For R8 to R9 only and customers having IP softphones, go to the Maximum IP Registrations by
Product ID screen (last screen) and verify that the number listed in the IP_Soft field did not
default to 1. If it did, get the number from field technician and type it in.
10
Press Enter to effect the changes.
11
Call the INADS database administrator at the TSC to verify that the system is part of the existing
INADS database.
12
Verify that INADS can dial into the system and that the system can dial out to INADS.
13
Log off and log back in as craft.

Reference

The INADS database administrator enables alarm origination and customer options as part of system
registration.
Return to Task List
Verify the upgrade [75 small upgrade]
Return to Task List
1
Execute
2
Type
display alarms
If the system is not alarm-free, take the needed corrective actions.
3
Type
list configuration software-version
(duplex) and press Enter. Check the Memory Resident field to verify that it shows the correct
software load.
316
and verify that the system is in a normal state.
status system 1
and press Enter.
status system 1
change system-parameters offer-options
and press Enter to set the customer
(simplex) or
list configuration software-version long
SI Installation and Upgrades
Avaya Support Web
and press
and press
June 2004