Add IP Solutions

Installing a TN802B in Media Processor Mode

Installing a TN802B in Media Processor Mode
Return to Task List
To operate in MedPro mode, you must install the TN802B IP Interface and, if the system does not have
one, you must also install and administer a TN799DP C-LAN circuit pack. For C-LAN administration,
refer to Administration for Network Connectivity for Avaya™ Communication Manager (555-233-504).
If you have existing TN802 IP Interface circuit packs, you can upgrade them either by replacing the
circuit pack with a TN802B or by downloading the TN802B firmware onto the circuit packs (see
Upgrade to TN802B (R10)

Task list: Install the TN802B in Media Processor mode

1
Prepare for Installation
2
Check your shipment
3
Connect the Cables for TN799x
4
Connect the Cables for TN802B
5
Connect the Modem
6
Connect the Ethernet
7
Install the Circuit Packs
8
Administer the TN799x C-LAN
9
Administer the IP Interface
10
Test the External Connection to the LAN
Prepare for Installation
Return to Task List
Have the following equipment on site before your shipment arrives:
AC power outlets for the modem and monitor.
Three unoccupied and adjoining port slots in the DEFINITY ECS for the TN802B IP Interface, if
needed.
The TN802B occupies only one slot, but it needs the two slots to its left for clearance.
A 10 BaseT or 10/100 BaseT Ethernet connection into your local area network for the TN802B.
One or more valid, unused IP addresses on your network that can be assigned to the IP Interface
server. You also need the subnet mask and default gateway.
An analog telephone line reserved (DID is okay) for the IP Interface diagnostic modem
A valid telephone number reserved for the IP Interface diagnostic modem
In addition if non-U.S. customer:
Modem comparable to a U.S. Robotics Sportster Model USR 33.6 EXT.
Cable from modem to TN802B external cable assembly.