Patch Cord/Jumper Installation and Administration

Before starting the patch cord installation, obtain a copy of the Port Assignment Record forms from the
customer or marketing representative. See
These forms contain the port assignments and identify the extension numbers (Terminal No.) of the
telephones/voice terminals. Enter the jack assignments at the equipment room and indicate if adjunct
power is required and where it is provided (MDF, site/satellite closet, or information outlet).
When satellite locations are provided, enter the satellite letter designation (A through F) and the jack
appearance in the equipment room on the form. Also, enter the floor designation and/or building
designation if appropriate. For 1-point administration, this entry is all that is required.
The white label identifying the terminal block row associated with circuits 17 to 24 connects to an
identically labeled terminal block row at the satellite closet. See
Information Outlet,
The satellite symbol must be installed at all connection points between the blue field and the information
outlet. It must also be installed at the information outlet itself.
Figure 154, Example 4-Pair Labeling to Information Outlet,
scheme for 4-pair circuits from the equipment room to the information outlets. The labeling scheme for 3-
pair circuits from the MDF to a satellite location.
Figure 152: Port Assignment Record Form
CARRIER
Slot
Port Jack* Old
01
02
03
04
05
06
07
08
09
10
11
Slot
12
13
14
CKT PK
15
Type
16
17
18
19
20
21
22
23
24
* To be completed by installation technician
SI Installation and Upgrades
June 2004
Figure 152, Port Assignment Record Form,
on page 430. This is always the case for either 1-point or 2-point administration.
PORT ASSIGNMENT RECORD
Extension
Voice
Voice
Bldg
Number
Terminal
Terminal
Flr
Adjunct
Rm
New
Type
Color
Install Telecommunications Cabling
Patch Cord/Jumper Installation and Administration
Figure 153, Example 3-Pair Labeling to
on page 431 shows an example labeling
Module
Power*
on page 429.
Page
User Name/Use
r764787 PDH 071596
429