Verify The Upgrade; Check Link Status - Avaya MCC1 Installation And Upgrades

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

Verify the upgrade

Return to Task List
1
Type
status system 1
The System 1 Status screen appears.
2
Check these fields for the corresponding values:
— In the SPE ALARMS section, MAJOR and MINOR alarms = 0
— In the four SERVICE STATE areas, ensure that the active (and standby -- High and
Critical Reliability) side(s) read in (service).
NOTE:
High and Critical Reliability: Following the upgrade, duplicated configurations enter into
a SPE maintenance interval that lasts approximately 50 minutes. When the Mode fields
indicate that one side is active and the other standby, then the SERVICE STATE fields
should read in.
You can continue with the upgrade, however some commands will be not be available
until the maintenance interval has completed.
3
If there are alarms, take the necessary corrective actions (
Return to Task List

Check link status

Return to Task List
1
Type
display communication-interface links
NOTE:
ISDN-PRI D-channel links no longer appear on this screen. (ISDN-PRI resides on the
network packet circuit pack.) The only way to determine if an ISDN-PRI D-Channel is up
is to use the
2
Type
status link number
3
Check that DS1 trunks and BRI phones are functioning normally.
4
Type
list signaling-group
5
For each signaling group, type
6
Ensure that the Group State field is in-service.
7
Execute the following commands and verify that the information is correct:
— list station
— list trunk-group
— list hunt-group
— list data-module
list ars analysis
— For a system with Expert Agent,
Return to Task List
SI Installation and Upgrades
June 2004
Release 9si/10si/Communication Manager 1.x to Communication Manager 2.1
Task list: R9si/10si/Communication Manager 1.x to Communication Manager 2.1
and press Return.
status signaling group
and press Return. Repeat this step for each type of administered link.
press Return.
status signal
list agent
display alarms
and press Return.
command.
<
> and press Return.
number
).
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1