Test Spe Duplication Memory Shadowing Link (If Duplicated); Test Duplicated Switch Processing Element Interchange (If Duplicated) - Avaya MCC1 Installation And Upgrades

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

Test the System
LED Indicators

Test SPE Duplication Memory Shadowing Link (if duplicated)

Return to Task List
1
Type
test shadow-link
2
Verify the screen displays test results similar to
Duplication Memory Shadowing Link,
Figure 186: Example Test Results for SPE Duplication Memory Shadowing Link
Port
Command successfully completed
Return to Task List

Test Duplicated Switch Processing Element Interchange (if duplicated)

Return to Task List
1
If Multi-Carrier Cabinet (MCC1), type status system
or
If Single-Carrier Cabinet (SCC1), type
2
Verify the screen displays test results similar to
Cabinets,
3
Note the MODE of SPE 1A and 1B .
4
Type
refresh spe
Command successfully completed
5
Type
reset system interchange
6
Log in as craft again.
NOTE:
If you have a dadmin login and password, you can use them instead of craft and the craft
password.
7
Note the MODE for SPE 1A and 1B should have changed from that noted in Step 3.
492
and press Enter.
Maintenance Name
Alt. Name Test No. Result
SHDW-LNK
on page 493.
and press Enter.
and press Enter. This causes the terminal to log off.
Figure 186, Example Test Results for SPE
on page 492.
TEST RESULTS
318
PASS
cabinet number <1-44>
status system all-cabinets
Figure 187, Example System Status Report for All
displays.
SI Installation and Upgrades
Error Code
and press Enter.
and press Enter.
June 2004