Station Wiring Design

The following hardware and cabling is used:

Information Outlets

Station Cables

Closets
— Site locations
— Satellite locations
A brief description of each of the above listed items follows. Ordering information is not provided for
station cables and information outlets.
Information Outlets
Information outlets are 8-pin modular wall jacks. Most of the outlets are wired with push-on connections.
Information outlets are also available that connect to a double modular plug-ended 4-pair station cable
routed from the MDF, a site/satellite location, or an adapter.
Station Cables
For clarity, a station cable is either a 25-pair cable, multiple 25-pair cable, or 4-pair D-inside wire (DIW)
run from the equipment room, site/satellite location, or adapter to the information outlets. The following
station cables are available. See
25-pair station cable
A25D cable (male to male) between the equipment room and satellite closet. Use a B25A cable between
the equipment room and site closet or adapter.
Multiple 25-pair station cable
adapters. This cable consists of individually sheathed 25-pair cables with a factory-installed 25-pair
connector on each end. Use a male to female cable to connect between the equipment room and site
location or adapter. Use a male to male cable to connect between the equipment room and satellite
location. Staggered-finger cables are recommended for all multiple 25-pair station cables and are
available in both double-ended and single-ended types.
Single modular plug-ended 4-pair station cable
outlets that require push-on connections. It can also be used when 4-pair station cables are field-
terminated on the 110-type terminal blocks in the equipment room or satellite closet and modularly
connected to information outlets. The station cables are available in the following lengths:
10 ft (3.05 m)
25 ft (7.62 m)
50 ft (15.24 m)
75 ft (22.86 m)
100 ft (30.5 m)
SI Installation and Upgrades
June 2004
on page 417 (modular wall jacks)
on page 417
on page 418
Figure 144, Example of Extending 4-Pair Station Cables,
Use between the equipment room and site/ satellite locations or adapters. Use an
Use between the equipment room and site/satellite locations or
Install Telecommunications Cabling
Use this cable between adapters and information
Station Wiring Design