Release 9si/10si/Communication Manager 1.x to Communication Manager 2.1
Task list: R9si/10si/Communication Manager 1.x to Communication Manager 2.1

Shut down DEFINITY AUDIX system

Return to Task List
A yellow caution sticker on the system's power unit notifies you to shut down the AUDIX before
powering down the system.
!
Neglecting to shut down an AUDIX assembly before powering down the system cabinet
where it resides can damage the AUDIX disk.
1
Log into the AUDIX as craft.
NOTE:
If you have a dadmin login and password, you can use them instead of craft and the craft
password.
2
Type
reset system shutdown
3
Press Return again to start the shutdown.
The
SHUTDOWN Completed
takes about 2 minutes.
!
If you are leaving the AUDIX System in the carrier, back it out about 2 in. (5 cm) to
eliminate the possibility of damage due to power surges.
Return to Task List

Determine active SPE

NOTE:
Perform this procedure on high and critical reliability systems.
Return to Task List
1
Type
status system 1
2
Determine which side is the active SPE.
3
The standby side should be in the standby state.