Locating logical switches using chassis beaconing

1. Select a logical switch using the drop-down list under Fabric Tree section in the Switch Explorer
2. Select Beacon for a switch, or Chassis Beacon for a chassis-based switch.
3. Look at the physical switches in your installation location to identify the switch.

Locating logical switches using chassis beaconing

Use the following procedure to locate all logical switches in a chassis.
1. Select a logical switch using the drop-down list under the Fabric Tree section in the Switch
2. Click Chassis Beacon.

Virtual Fabrics overview

Virtual Fabrics is an architecture that virtualizes hardware boundaries. Traditionally, SAN design
and management is done at the granularity of a physical switch. Each switch and all the ports in
the switch act as a single fabric element that participates in a single fabric. Virtual Fabrics allows
SAN design and management to be done at the granularity of a port. This enables partitioning of a
physical switch into multiple logical switches, which may be organized into logical fabrics.
The following platforms are Virtual Fabrics-capable:
Virtual Fabrics cannot be configured or managed from Web Tools. Configuration and management
is done from either the Data Center Management Program (DCFM), or the Fabric OS command line
interface. For information about configuring and managing Virtual Fabrics, refer to the DCFM User
Manual if you are using DCFM, or Fabric OS Administrator's Guide if you are using the Fabric OS
command line interface.
You can use Web Tools to view Virtual Fabrics and logical switch configurations.

Selecting a logical switch from the Switch View

You can log in to a specific logical switch, as described in Chapter 1, or you can select a logical
switch from the Switch View. If you do not log in to a specific logical switch, you are presented with
the default logical switch.
58
DRAFT: BROCADE CONFIDENTIAL
window.
The selected switch displays in the Switch View.
The LED lights on the actual switch light up on the physical switch in a pattern running back
and forth across the switch itself. In chassis-based switches, the LEDs glow across all the
blades.
Explorer window.
The selected switch displays in the Switch View.
The LEDs on the logical switch light up on the blades associated with the logical switch.