Finding The Physical Chassis For A Logical Switch; Finding The Logical Switch From A Physical Chassis; Assigning Ports To A Logical Switch - Brocade Communications Systems Brocade BladeSystem 4/24 User Manual

Supporting dcfm 10.4.x
Hide thumbs Also See for Brocade BladeSystem 4/24:
Table of Contents

Advertisement

19. Select the Re-Enable ports after moving them check box.
20. (Optional) Select the Unbind Port Addresses while moving them check box.
21. Click Start to send these changes to the affected chassis.
22. When the changes are complete, click Close.
23. If the newly created switch is not part of a discovered fabric, then you must discover the

Finding the physical chassis for a logical switch

The Management application enables you to locate the physical chassis in the Product List from
which the logical switch was created.
To find the physical chassis for a logical switch, right-click the logical switch in the Connectivity Map
or Product List and select Chassis.
The physical chassis is highlighted in the Product List.

Finding the logical switch from a physical chassis

The Management application enables you to locate the logical switch from the physical chassis.
To find the logical switch, right-click the physical chassis within the Chassis Group in the Product
List and select Logical Switches > Logical_Switch_Name.
The logical switch you selected is highlighted in the Product List and Connectivity Map.

Assigning ports to a logical switch

A port can be assigned to only one logical switch.
All ports are initially assigned to the default logical switch. When you create a logical switch, it has
no ports and you must explicitly assign ports to it.
When you assign a port to a logical switch, it is removed from the original logical switch and
assigned to the new logical switch.
DCFM Professional Plus User Manual
53-1001774-01
The Logical Switch Change Confirmation and Status dialog box displays with a list of all
changes you made in the Logical Switches dialog box.
NOTE
Ports are disabled before moving from one logical switch to another.
NOTE
Most changes to logical switches will disrupt data traffic in the fabric.
The status of each change is displayed in the Status column and Status area in the dialog box.
switch.
a. Undiscover the physical chassis. See
b. Rediscover the physical chassis. See
When entering the IP address, use the IP address of the physical fabric.
"Deleting a fabric"
on page 41 for instructions.
"Discovering fabrics"
on page 36 for instructions.
19
559

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcfm professional plus

Table of Contents