FA
Start Frequency
real
The FA command specifies the start frequency value. The function is identical with that of the front panel
key The program line below illustrates command syntax.
When queried (? or OA), FA returns the start frequency value, a real number, followed by carriage-return/line-
feed (ASCII codes 13, 10). The end-or-identify state (EOI) is asserted with line feed.