Checking System And Slot Status - Lucent Technologies MERLIN LEGEND Release 6.1 Maintenance And Troubleshooting Manual

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140

Checking System and Slot Status

Remove the processor, the power supply, and all other modules
from the faulty carrier. (If you prefer to remove the cords first, make
sure that they are labeled.)
Put the modules aside, in order, so that you can reinstall them later
in the replacement carrier.
Remove all modules from the carriers to the right of the faulty
carrier.
Starting with the rightmost carrier, loosen the four screws that
secure the four corners of the carrier to the backboard.
Slide the carrier to the right until the connector disengages from the
carrier to the left.
Pull the carrier away from the wall so that the screws slip through
the large screw holes.
Repeat Steps 8–10 until the faulty carrier is removed.
Replacing the Carrier
After removing the faulty carrier, use the steps below as a guideline for installing
a new carrier.
Install the replacement carrier(s). See Installation for instructions.
Replace the modules with all cords connected as they were before.
Checking System and Slot Status
In addition to checking error logs, and the access log, and running module tests,
you can request System Status and Slot Status information for each module.
Issue 1
August 1998
Page 4-128

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merlin legend

Table of Contents