Lucent Technologies MERLIN LEGEND Release 6.1 Maintenance And Troubleshooting Manual page 198

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
800 NI-BRI Module Problems
Table 4–7. Continued
Result
Code
Description
Error in LEGEND
(Release
administration of
4.1 and
DN and/or CO
later)
provisioning error
for voice calls on
that facility
Error in LEGEND
(Release
administration of
4.1 and
DN and/or CO
later)
provisioning error
for data calls on that
facility
Corrective Action
The facility is correctly programmed and
established with layers 1, 2, and 3. However,
no incoming voice calls can be received.
Check that the facility is programmed with the
DN provided by the LEC.
If the facility is part of an MLHG, check if the
voice MLHG DN is absent. If the voice MLHG
DN is absent, administer it and rerun the test.
The possible causes of this error are:
Incorrect DN/MLHG DN
Incoming voice calls are not possible;
error identified at Incoming Voice Call Test
(page
4-95), Step 2, and the DN and MLHG
DN cannot be verified.
The facility is correctly programmed and
established with layers 1, 2, and 3. However,
no incoming data calls can be received.
Check that the facility is programmed with the
DN provided by the LEC.
If the facility is part of an MLHG, check if the
data MLHG DN is absent. If the data MLHG
DN is absent, administer it and rerun the test.
The possible causes of this error are:
Incorrect DN/MLHG DN
Incoming data calls are not possible; error
identified at Incoming Voice Call Test
4-95), Step 2, and the DN and MLHG DN
cannot be verified.
Issue 1
August 1998
Page 4-86
(page
Continued on next page