Lucent Technologies MERLIN LEGEND Release 6.1 Maintenance And Troubleshooting Manual page 73

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
Error Logs
Table 2–2. Error Codes (Continued)
Error
Codes
Description
A module dual port RAM failure was
detected.
System programming is okay.
Date and/or Time incorrect or
unreadable.
This error is not displayed.
The system performs a cold start
because the real time clock chip is
not working correctly.
A PCMCIA memory card for
Translation is not inserted.
A PCMCIA card other than a
Translation card is inserted.
The Translation card has the write
protection switch on.
This error indicates that the VMS
machine may be down.
May be noisy line or central office
problem.
Action
If problem persists, troubleshoot the
module for the slot indicated.
If this problem persists, replace the
processor module.
If this problem persists, replace the
processor module.
Insert a Translation card or a card that
has not been formatted.
Remove the current card and insert a
Translation card or a card that has not
been formatted.
Flip the write protection switch on the card
to off (non-write protect mode/position.) It
this problem persists, try another card,
then replace the processor module if the
problem remains.
No action required.
No action required. If problem persists,
troubleshoot the DID line and inform the
central office if necessary.
Continued on next page
Issue 1
August 1998
Page 2-9