Installation
Wall-Mounting a 2-Slot Carrier and Modules
To wall-mount a 2-Slot Carrier, first follow the instructions in "Wall-Mounting a
Stand-Alone PARTNER ACS Processor Module".
NOTE:
To add a 308EC module to a PARTNER ACS processor module, the
PARTNER ACS processor module must already be mounted on the wall.
Before starting, disconnect the power cord from the power jack. If it is not
mounted, refer to "Wall-Mounting a Stand-Alone PARTNER ACS
Processor Module" on the previous page for instructions. Then follow the
instructions below.
Use the following procedure to install a 400, 308EC, or 206 or PARTNER MAIL
VS module as the second module:
1
Remove the clear plastic protector from
the connector on the right side of the
new 308EC module by grasping the tabs
on the ends of the protector and lifting. If
you are upgrading from a stand-alone
system, also remove the protector from
the wall-mounted PARTNER ACS
processor module.
2
a. Remove the #8 sheet metal screw or
screws from the bottom of the
wall-mounted module or modules.
b. If you are upgrading an existing
single module system, skip to Step
4b.
3
If you are replacing the second module
in a 2-Slot Carrier, remove the two #4
screws holding the carrier in place and
gently pull the carrier off the modules.
12