MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
800 NI-BRI Module Problems
Table 4–7. Continued
Result
Code
Description
continued
CO provisioning
error for data calls
on that facility
Corrective Action
Provisioning on the facility does not
always allow outgoing and/or incoming
calls. Error identified at Outgoing Voice Call
Test, Step 4 and/or Incoming Voice Call Test,
Step 2.
This condition may or may not be detected by
any single manual test. Therefore, a
sequence of calls may be necessary to
determine the condition for the failure.
The facility is correctly programmed and
established on Layers 1, 2, and 3. However, a
problem associated with the provisioning at
the CO for data calls was detected.
If the facility is intended to provide data calls,
perform the following tests with either digital
data terminals or analog data terminals and
modem pools. Record the results before
contacting the LEC:
Outgoing Data Call Test (see
Incoming Data Call Test (see
If data terminals are not available, contact the
LEC and advise them that the provisioning for
data on the facility requires checking. If more
information is required, contact the NSAC
and provide them with the result code, the
slot number, the port number, and the site
information (remote access number, etc.).
Issue 1
August 1998
Page 4-84
page
4-96)
page
4-97)
Continued on next page