Lucent Technologies MERLIN LEGEND Release 6.1 Maintenance And Troubleshooting Manual page 52

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
Maintenance Strategy
Frigid Start (System Erase)
!
CAUTION:
All system programming is erased. When you perform a frigid start
(System Erase), all calls are dropped, and the system configuration
information is erased. All system memory must be reinitialized, including
system programming. Then the entire system must be rebooted.
To perform a frigid start, select
Console Procedure
PC Procedure
Considerations
, press the left button on Line 5 of the display twice.
After a System Erase, the default printer is the PC printer, not the Station
Message Detail Recording (SMDR) printer. If you want onsite printouts from the
SMDR printer, make sure you change the option.
To change the printer option, see System Programming and Maintenance
(SPM) for information about the Print Opts option on the SPM Main Menu.
For more information about System Erase, see
page
4–12..
Isolating the Trouble
You can isolate any problem to one of the following areas:
Telephone
Control unit
Menu:
button)
is not displayed on the MLX-20L status display. To select
as follows:
Dial
(Line 5 of the display, left
Type
"See "Processor Problems" on
Issue 1