Table 2–2. Error Codes (Continued)
Error
Codes
Description
No loop current on an outgoing call.
If this error occurs four times
consecutively, and if Automatic
Maintenance-Busy is enabled and
the 50% maintenance-busy limit has
not been exceeded, the trunk is
busied-out automatically.
Communication problems between
the module and central office.
No loop current.
If this error occurs four times
consecutively, and if Automatic
Maintenance-Busy is enabled and
the 50% maintenance-busy limit has
not been exceeded, the trunk is
busied-out automatically.
Communication problems between
the module and central office.
If this error occurs twice
consecutively, the trunk is
busied-out automatically, whether or
not Automatic Maintenance-Busy is
enabled.
Action
Test the trunk with a single-line
telephone. If the problem is not in the
trunk, replace the module with one that is
known to be working. If the problem is
gone when using the known good
module, replace the module and restart.
Test the trunk with a single-line
telephone. If the problem is not in the
trunk, replace the module with one that is
known to be working. If the problem is
gone when using the known good
module, replace the module and restart.
Test the trunk with a single-line
telephone. If the problem is not in the
trunk, replace the module with one that is
known to be working. If the problem is
gone when using the known good
module, replace the module and restart.