Lucent Technologies MERLIN LEGEND Release 6.1 Maintenance And Troubleshooting Manual page 189

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
800 NI-BRI Module Problems
Summary
Busy-Out or Reset
Console Procedure
PC Procedures
Appropriate Modules
Time Estimate
Interrupting the Test
Test Failure
Restore
To run the provisioning test, follow the steps below.
NOTE:
Before proceeding with this test, obtain completed copies of System
Planning Form 3-i, Incoming Trunks: BRI Options and the NI-1 BRI
Planner Form.
Before beginning the test, busy-out or reset the module
being tested. Both Busy-Out and Reset are on the Slot
menu, which you can access by doing the following from
the console:
Menu
See
''Restore'' on page 4-45
Menu
Type the BRI slot no.
This test can be run only on 800 NI-BRI modules.
Approximately 20 minutes for a fully utilized board.
However, communication paths with errors increase the
time. Boards with fewer programmed lines and no errors
decrease the time.
Interrupt the test by selecting
If the test fails, follow the instructions in
Table
4–7. If the module must be replaced, record the
errors on the repair tag and replace the module.
Restore the module when it completes all module tests.
is on the Slot menu, which you can access by
doing the following from the console:
Menu
See
''Restore'' on page 4-45
August 1998
Page 4-77
for additional information.
Dial the BRI slot no.
.
Table 4–6
for additional information.
Issue 1
and in