Lucent Technologies MERLIN LEGEND Release 6.1 Maintenance And Troubleshooting Manual page 283

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
Checking Ports
Console Display/Instructions
The screen below appears only if the audit message is successfully
created and sent.
BChannel
Audit Initiated
Exit
After about four minutes, check the error logs.
If new PRI errors occur, contact your technical support
organization for help on interpreting the results and your action.
If no new PRI messages appear, the ends are most likely in
agreement.
The screen below appears when the message cannot be sent due to
signaling failure.
BChannel
Audit Failed
Exit
This indicates that the problem may be at the CO end. First, make sure
the correct B-channel is selected. If the correct B-channel is selected, the
customer or Lucent Technologies representative acting as the
customer's agent should ask the CO to clear the problem from that end.
If the problem is not at the CO end, select the correct B-channel and
repeat the Audit Lines procedure.
YYYY
Audit Line
YYYY
Audit Line
Additional Information
xxxx = slot and port number entered
in Step 3.
xxxx = slot and port number entered
in Step 3.
Issue 1
August 1998
Page 5-37
PC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merlin legend

Table of Contents