MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
800 NI-BRI Module Problems
Table 4–7. Continued
Result
Code
Description
No administration or
incorrect
administration on
that facility
Corrective Action
Check that the facility is programmed with the
SPID and DN provided by the CO. If the SPID
and DN were not programmed properly,
correct it and rerun the test. If an error
persists, perform the appropriate set of tests
(voice only, data only, or voice and data) and
record the results before contacting the LEC:
Outgoing Voice Call Test
Incoming Voice Call Test
or
Outgoing Data Call Test
Incoming Data Call Test
The possible causes of this error are:
Incorrect SPID. Error identified at Incoming
Voice Call Test, Step 3; Incoming Voice Call
Test, Step 2; Outgoing Data Call Test, Step 2;
and/or Incoming Data Call Test, Step 2. Both
outgoing and incoming calls fail.
Incorrect DN. Error identified at Incoming
Voice/Data Call Test, Step 2. Incoming calls
fail.