MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
800 NI-BRI Module Problems
Console Display/Instructions
If the test cannot be run to completion, an error message screen
appears, such as the one shown below.
Find the error message in
Table 4–6. NI-1 BRI Provisioning Test Errors
Error Messages
'
(Release 4.1 and later)
Additional Information
xx = slot number entered in
Step 2
Table 4–6
and proceed as indicated.
Corrective Action
Exit the test, busy-out the slot, and try again.
Exit the test and try again. Be sure to type the
correct slot number; do not indicate an empty slot or
the processor (00). If the problem persists, replace
the 800 NI-BRI module.
Exit the test. Remove half of the DSL connectors
and rerun the test. Note the result codes of those
that fail and then disconnect them. Reconnect the
untested DSLs and rerun the test. Note those that
fail. Reconnect all DSLs.
Check that all BRI boards not being tested are
busied out and unplugged from the carrier. Run the
test again.