MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
Unit Load Worksheet
Unit Load Worksheet
1. Number of modules in carrier (excluding power
supply and processor):
2. Key or Behind Switch mode only:
Indicate configuration of lines; then go to Step 5.
3. Hybrid/PBX mode only:
Do all modules in the carrier have MLX and/or
analog multiline telephone jacks?
4. Hybrid/PBX mode only:
Calculate the total number of MLX and analog
multiline telephones:
Number of MLX-20L consoles connected to
modules in the carrier
Number of MLX-28D consoles connected to
modules in the carrier
Number of 34-button analog multiline telephones
connected to modules in the carrier
Total of MLX-20L, MLX-28D, and 34-button analog
telephones
If fewer than five, power is adequate.
If five or six, continue to Step 2.
If no, a newer power supply is not needed.
If yes, continue to Step 4.
If total is less than or equal to 45, auxiliary
power is not required.
If the total is greater than 45, continue to
Step 5.
Issue 1
August 1998
Page C-2
__________
Square
Modified
Yes
No
__________
__________
__________
__________