Lucent Technologies MERLIN LEGEND Release 6.1 Maintenance And Troubleshooting Manual page 137

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
Processor Problems
If the installation of system software was unsuccessful, an error code is
displayed and the system may not function. See
Conditions During Forced Installation'' on page
Remove the memory card from the interface slot.
Verify that system software has been correctly installed and that the
default system programming is present.
No error condition is displayed on the error/status display.
Restore system programming.
After about 10 minutes, check to see if the RED alarm status LED is lit. If
it is not, the installation was successful. If the LED is lit, check the error
log for the following:
This indicates a ROM failure and unsuccessful installation.
If the forced installation was performed due to corrupted system
software, it is possible that the backup of system programming might
also be corrupted. Verify that the error condition that required a forced
installation of software is not still present.
Error Conditions During Forced Installation
The error code/status display on the processor module or the maintenance
screen informs you of problems during or after a forced installation. See
4–2
for error codes displayed. Also see the screens following the table for errors
displayed on the maintenance console or PC.
The following error conditions can occur only during or immediately after a
forced installation. Instructions for recovery follow the description of each error
condition.
August 1998
Page 4-25
Table 4–2
and
''Error
4-25.
Issue 1
Table

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merlin legend

Table of Contents