MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
Module Problems
For MLX modules (008 MLX and 408 GS/LS-MLX) and 800 NI-BRI
modules, continue with the B-Channel Loopback test.
See "B-Channel Loopback Test" on page 4–57.
them as described in
For 800 NI-BRI modules, continue with the NI-1 BRI Provisioning
Test.
See "800 NI-BRI Module Problems" on page 4–75.
them as described in
For 100D modules, continue with the CSU loopback test.
See "100D Module Problems" on page 4–100.
them as described in
Replace the module with a module of the same type, whether you
are troubleshooting or replacing the module permanently.
Restore the module.
Menu
Restoring automatically undoes the busy-out and reset. For additional
information about restoring a module, see
Persistent Module Problems
If any of the module tests fail and replacing the module does not clear the
trouble, then either several modules may be faulty or the connector on the
carrier may be faulty.
Busy-Out and Reset
Before running any module test, be sure to busy-out or reset the module.
Busy-out discontinues service from the module being tested to each line
and extension only as they become idle. Busy-out is the preferred
method, because it does not disrupt calls in progress.
Reset discontinues service to all lines and extensions on the module
instantly.
''Considerations'' on page
''Considerations'' on page
''Considerations'' on page
Dial the slot no.
If errors occur, record
4-36.
If errors occur, record
4-36.
If errors occur, record
4-36.
''Restore'' on page
Issue 1
August 1998
Page 4-38
4-45.