800 NI-BRI Module Problems
Interpret the test results.
If the test completes successfully, the module's B-channels are
functioning properly. If a communication path fails, find the result code in
Table 4–7
Restore the module when all tests are completed.
When all of the lines have passed the test, the red LED remains on until
the CO reinitializes all of the lines.
Follow the procedures in
and make corrections, if necessary, before rerunning the tool.
Table 4–7. NI-BRI Test Result Codes
Result
Code
Description
BRI facility
provisioned with
(Release
functioning voice
4.0 and
and data
earlier)
capabilities
CO provisioning
error for voice calls
on that facility
and proceed as indicated.
Table 4–7
Corrective Action
No action required if voice and data functions
are expected.
The facility is correctly programmed and
established on Layers 1, 2, and 3. However, a
problem associated with the provisioning at
the CO for voice calls was detected.
If the facility is intended to provide voice calls,
perform the following tests and record the
results before contacting the LEC:
Outgoing Voice Call Test
Incoming Voice Call Test
to examine each BRI line that has an error
Issue 1
August 1998
Page 4-82
(page
4-94)
(page
4-95)
Continued on next page