800 NI-BRI Module Problems
Table 4–7. Continued
Result
Code
Description
No data hunting, or
(Release
Incorrect data
4.1 and
MLHG DN if MLHG
later)
DN is present, or
Data hunting was
observed with no
MLHG DN
Corrective Action
The facility is correctly programmed and
established with layers 1, 2, and 3 with
functioning data capabilities.
The possible causes of this error are:
Incoming data calls using the MLHG DN
are not possible, but incoming data calls
using the DN are possible. If data hunting is
expected, with the programmed MLHG DN,
check that the facility is programmed with the
MLHG DN provided by the LEC and rerun the
test. If the error persists, contact the LEC.
Incoming data calls using either the MLHG
DN or DN are not possible, and both the
MLHG DN and DN have been verified to be
correct. Reprogram the MLHG DN or DN and
rerun the test. If the error persists, contact the
LEC.
MLH is not expected. The MLHG DN is not
programmed and data calls to the facility
using the DN are terminated at the facility as
a hunt call. Contact the LEC.