Siemens SSC EWSD Switch Translations
The Siemens SSC EWSD switch provides for either voice or data hunting on
one DN via the Series Completion feature. The same provisioning is used for
either a voice or data series completion group.
ISDN Capability Package "S"
The information listed below provides the DN translations that define Capability
Package "S," and the screens and fields that must be populated.
The information provided shows the translations for one DSL and two DNs. For
multiple DSLs/DNs, the CO will duplicate these screens and enter the
applicable DSL and DN values as needed.
ISDN Ordering Code: Capability S
DISPACCESS:EQN=20-0-5-4;
ACCESS DATA
EQN =20-0-5-4,
CLOSS = 0,
BCHEQN =2,
BCEQN = SP
CPDDN = 2156855917-VI
CPVDN2 = 2156855917,
COE = CLASS1,
LINKOPT = DYNNOPAL,
BAPROF = 0;
DISPSUB:DN=6855917;
NPA = 215
CAT = IBA
BCHDN = 2
BCDN = SP
CT = VI
LCC = BVCE
BCHCT = 2
IBCHCT = 2
OBCHCT = 2
PIC = 0288-SP
& AU3
& C56
& 2156855917-CMD,
DN = 6855917
EQN = 20-0-5-4
&AU3
RAX = 1
EXEC'D
MASKNO:04328
MASKNO:00000
& C64,
&C56
&C64