Unit Load Calculation Worksheet
C
If you determine that you need to recalculate the unit load for any carrier, use
the instructions on the following worksheet.
NOTES:
1. You should have a separate copy of the worksheet for each carrier.
2. See
''Unit Loads'' on page 1-35
loads.
The 391C1 or 391A3 power supplies have a maximum rating of 75 unit loads. If
your system contains a 391A1 or 391A2 power supply module, and the unit
loads for that carrier will exceed 54, it is recommended that a 391A3 power
supply be installed in the system. Auxiliary Power Units cannot be used with the
391A3 power supply.
for information on recalculating unit
Issue 1
Issue 1