Table 4–4. Board Controller Test Errors
Error Messages
Any other error
Restoring the Module
When you are finished running module tests, be sure to restore the module. See
''Restore'' on page
B-Channel Loopback Test
This test verifies that specific communication paths on the MLX or 800 NI-BRI
modules are operational. If you have not read
4-34, do so.
Corrective Action
Exit the test, busy-out the slot, and try again.
Exit the test and try again; be sure to type the correct
slot number. Do not indicate an empty slot or the
processor (00).
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Record the errors on the repair tag and replace the
module.
4-45.
''Module Test Process'' on page