Lucent Technologies MERLIN LEGEND Release 6.1 Maintenance And Troubleshooting Manual page 77

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
Error Logs
Table 2–2. Error Codes (Continued)
Error
Codes
Description
A 64 kbps clear-channel data call was
routed to a facility that does not have
sufficient bandwidth to handle the call.
The error logs are full, and no more
errors can be added to them.
Turns on the processor LED.
This error is logged after a System
Erase. If the System Erase is
successful, this error is removed
immediately.
This is just a record of the event.
The system needed to use a trunk in a
pool but no trunks were physically
present in the pool, that is, all of the
boards were removed from the
system. See first argument number on
the screen for pool index (1–11).
:
:
Action
Verify that the ARS or UDP routing tables
route a data call to a DS1 facility. Check
the DS1 Type administration item for the
specified facility. If the programmed value
is T1 , the caller must initiate a 56 kbps
call. Check the DS1 Suppression
administration item for the specified
facility. If the programmed value is
AMI-ZCS , the caller must initiate a 56
kbps call.
Correct indicated errors, and then remove
entries from the transient system error log
to free up space. If problem persists,
cold-start the system before continuing
with troubleshooting.
If this error remains in the transient log, do
the System Erase again. If problem
persists, troubleshoot the processor.
No action required.
Check that the pool has a trunk assigned
to it. If a trunk is assigned and the
problem persists, replace the boards.
Continued on next page
Issue 1
August 1998
Page 2-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merlin legend