Lucent Technologies MERLIN LEGEND Release 6.1 Maintenance And Troubleshooting Manual page 85

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
Error Logs
Table 2–2. Error Codes (Continued)
Error
Codes
Description
A module error or processor error
resulted while running test.
Reported during cold start.
Memory failed the RAM test. Turns on
the processor LED.
Memory failed the ROM test. Turns on
the processor LED.
Memory failed the ROM test. Turns on
the processor LED.
Currently not reported.
Outbound dialing problems on tie
trunks. For a tie trunk with delay dial
or wink start, the wink from the far end
of the network interface is less than
the minimum 100 ms. The tie trunk
remains waiting for a valid signal.
Action
Reset the board. If problem persists,
troubleshoot the module.
If problem persists, troubleshoot the
module.
If problem persists, replace the processor.
If problem persists, replace the processor.
If problem persists, replace the processor.
No action required.
Troubleshoot the far end of the network
interface to see if it is working and
translated properly. Troubleshoot for
faulty cable. Replace the module.
Continued on next page
Issue 1
August 1998
Page 2-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merlin legend

Table of Contents