Table 2–2. Error Codes (Continued)
A message to update non-local
Message Waiting lights has
exceeded the time period for
delivery. A transient alarm occurs
after one minute, and a permanent
alarm occurs after 15 minutes. The
alarm remains in the error log until a
message is delivered or five days
pass.
More than half the trunks in the pool
are busy.
Incompatibility problem. The specified
video system or data device is
connected to an 008 or 408 GS/LS
MLX with firmware vintage 0x29.
Check the error log for additional error
codes. If the error log contains errors
indicating problems with the 100D
module, troubleshoot the 100D module
using instructions in Chapter 4 of this
guide. If the error log also contains erros
indicating problems with the 400EM
module, troubleshoot the module using
instructions in Chapter 4 of this guide.
If the 100D and/or the 400EM modules
are functioning properly, troubleshoot the
trunks using instructions in Chapter 5 of
this guide.
Check that the system receiving the
message has enough TTRs to handle the
volume of calls. Check the error logs on
the sending system and then on the
receiving system-more facilities may be
needed.
Troubleshoot trunk.
Slot did not complete initializing.
No action required.
No action required.
Replace the 008 or 408 MLX board with
one of another firmware vintage and retire
this permanent alarm manually.