Dial The Slot No - Lucent Technologies MERLIN LEGEND Release 6.1 Maintenance And Troubleshooting Manual

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
Module Problems
Summary
Console Procedure
PC Procedures
Appropriate Modules
Time Estimate
Busy-Out or Reset
Interrupting the Test
Test Failure
Restore
To run the B-Channel Loopback Test, follow the steps below.
Menu
no.
Type the slot no.
This test can be run only on MLX or 800 NI-BRI
modules.
Approximately 1.5 minutes.
Before beginning the test, busy-out or reset the
module being tested. Both Busy-Out and Reset are in
the Slot menu, which you can access by doing the
following from the console:
Menu
See
''Busy-Out and Reset'' on page 4-38
information.
Interrupt the test by selecting
If the test fails, record the errors on the repair tag and
replace the module.
Restore the module if it successfully completes all
module tests and the errors no longer occur.
is in the Slot menu, which you can access by doing the
following from the console:
Menu
See
''Restore'' on page 4-45
August 1998
Page 4-58
Dial the slot
for additional
.
for additional information.
Issue 1