Burninerrclear - Brocade Communications Systems A7990A - StorageWorks SAN Director 4/16 Blade Switch Command Reference Manual

Brocade fabric os command reference manual (53-1000240-01, november 2006)
Hide thumbs Also See for A7990A - StorageWorks SAN Director 4/16 Blade Switch:
Table of Contents

Advertisement

Note: Enter commands in lowercase only; mixed case is for readability.
2

burninErrClear

burninErrClear
Clears errors stored in the nonvolatile memory on the slot during burn-in.
Synopsis
burninerrclear slotnumber
Description
Use this command to clear errors stored in the nonvolatile memory on the slot during burn-in.
Note
It is advisable to run the
Note
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands
The operand is a follows:
slotnumber
Examples
To clear burn-in errors from slot 2.
switch:admin> burninerrclear 2
See Also
burninErrShow
2-46
burninErrClear
command prior to running
A nonzero value that specifies the slot number from which to clear burn-in errors.
diagSetBurnin
and diagSetCycle.
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01

Advertisement

Table of Contents
loading

Table of Contents