Brocade Communications Systems A7990A - StorageWorks SAN Director 4/16 Blade Switch Command Reference Manual page 271

Brocade fabric os command reference manual (53-1000240-01, november 2006)
Hide thumbs Also See for A7990A - StorageWorks SAN Director 4/16 Blade Switch:
Table of Contents

Advertisement

Note: Enter commands in lowercase only; mixed case is for readability.
Operands
This command has the following operands:
-nframes count
-ports itemlist
-seed payload_pattern
-width pattern_width Specify the width of the pattern that the user specified. Valid values are:
-size pattern_size
Examples
To run
switch:admin> fporttest -ports 1/0-1/15
Running fPortTest .......
Test Complete: "fporttest" Pass 10 of 10
Duration 0 hr, 0 min & 1 sec (0:0:0:127).
passed.
Diagnostics
The following are possible error messages if failures are detected:
DATA
INIT
PORT_DIED
EPI1_STATUS_ERR
ERR_STAT
ERR_STATS
ERR_STATS_2LONG
ERR_STATS_BADEOF
ERR_STATS_BADOS
ERR_STATS_C3DISC
ERR_STATS_CRC
ERR_STATS_ENCIN
ERR_STATS_ENCOUT
ERR_STATS_TRUNC
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
Specify the number of times (or number of frames per port) to execute this test. If
count is omitted, the default of 10 is used. This operand is optional.
Specify the ports to test. If itemlist is omitted, the test is executed on all online
F_Ports in the specified slot. This operand is optional.
Specify the pattern of the test packets payload. Valid values are:
0
CSPAT (default)
1
BYTE_LFST
2
CHALF_SQ
3
QUAD_NOT
4
CQRT_SQ
5
CRPAT
6
RANDOM
All other values are modularized into one of these values.
1
byte (default)
2
word
4
quad
This operand is optional.
Specify the number of words in the test packet payload. If pattern_size is omitted,
the default value is 512. This operand is optional.
fportTest
on a switch:
2
fportTest
2-237

Advertisement

Table of Contents
loading

Table of Contents