Note: Enter commands in lowercase only; mixed case is for readability.
2
portLogShow
ctout
errlog
loopscn
Codes used in various fields are as follows:
state
2-494
disable State (refer to state codes next)
enable Mode: 0 normal; non-zero loopback
Tx & RxHeader words 0,1,4 (R_CTL,D_ID,S_ID,OX_ID,RX_ID) and the first
payload word
reject
FC-PH reject reason
busy
FC-PH busy reason
ctin
Argument 0 is divided into two 16-bit fields:
[A] a bit map indicating whether subsequent args are valid (0001 means
argument 1 is valid, 0003 means arguments 1 and 2 are valid).
[B] the CT-based service command code.
Argument 1 is the first word of the CT payload, if applicable (as specified
in [A]).
Argument 2 is the second word of the CT payload, if applicable (as
specified in [A]).
Argument 0 is also divided into two 16-bit fields:
[A] a bit map indicating whether subsequent args are valid (0001 means argument
1 is valid, 0003 means arguments 1 and 2 are valid).
[B] the CT command code indicating whether an accept (8002) or a reject (8001).
If [B] is an accept, argument 1 and 2 represents the first and second words of the
CT payload, if applicable (as specified in [A]).
If [B] is a reject, argument 1 contains the CT reject reason and explanation code.
Error type (refer to errShow)
The meaning further depends on each loop state:
OLP
Offline reason code, usually zero
LIP
Reason code for LIPs initiated by FL_Port, if the code value is 800x (x =
[1,0xc], see below), or the lower two bytes of the LIP received, if the
code value is other than 800x
LIM
Usually zero
BMP
Memory address for the loop bitmap
OLD
Usually zero
TMO
Encoded value of the state when loop init timed out This value is usually
equal to the first word of a loop init frame payload. Other possible values
include:
2
LIP (req. INITIALIZING) timeout
94F0F0 ARB(F0) timeout
40
CLS timeout
Fabric OS Command Reference Manual