Note: Enter commands in lowercase only; mixed case is for readability.
portScn
port generation number
portId
portIfId
portWwn
portWwn of devices(s) connected
Distance
portSpeed
EX_Port Mode
Fabric ID
Front Phantom
Pr Switch Info
BB XLate
Authentication Type If the EX_Port is connected to an edge switch with no security, then the
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
No_Light
Module is not receiving light.
No_Sync
Receiving light but out of sync.
In_Sync
Receiving light and in sync.
Laser_Flt
Module is signaling a laser fault.
Port_Flt
Port marked faulty.
Diag_Flt
Port failed diagnostics.
Lock_Ref
Locking to the reference signal.
Last State Change Notification for port.
Port generation number for the last offline state change.
24-bit port ID.
User port's interface ID.
Port WWN.
WWNs of connected devices.
The port's long-distance level. In case of LD mode, the user configured desired
distance and actual distance also are displayed. Refer to portCfgLongDistance.
The port's fixed speed (1, 2, or 4 Gbit/sec) or negotiated speed (N1, N2, N4 Gbit/
sec or AN).
The port is configured as an EX_Port. None of the EX_Port information is
displayed if the port is not configured as an EX_Port.
The fabric ID assigned to this EX_Port; therefore, it is the fabric ID of the edge
fabric attached to this EX_Port.
Information on the front phantom domain presented by this EX_Port. This
information includes the preferred (if not active) or actual (if active) domain ID
for the front domain and the WWN of the front domain.
Information on the principal switch of the edge fabric attached to this EX_Port.
This information includes the domain ID and WWN of the principal switch.
Information on the xlate (translate) phantom domain presented at this port. This
information includes the preferred (if not active) or actual (if active) domain ID
for the xlate phantom domain and the WWN of the xlate phantom domain . The
xlate phantom domain connected at this port is in the same fabric as the router and
represents the edge fabric connected to the EX_Port.
authentication is displayed as "None". If the edge switch is in secure mode, and