Note: Enter commands in lowercase only; mixed case is for readability.
Note
This command requires a Brocade Advanced Performance Monitoring license.
This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE
ports.
Note
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands
The operands are as follows:
--class monitor_class The monitor class, which can be one of EE (end-to-end), FLT (filter-based), or
slotnumber
portnumber
interval
Examples
To display end-to-end monitor on a port at an interval of every 6 seconds:
switch:admin> perfmonitorshow --class EE 4/5 6
perfmonitorshow 53, 6: Tx/Rx are # of bytes and crc is # of crc errors
------------- ------------- ------------- ------------- -------------
crc
============= ============= ============= ============= =============
0
0
0
0
0
0
0
0
0
0
0
0
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
ISL (interswitch link). These values are case-sensitive.
For bladed systems only, this operand specifies the slot number of the port on
which the monitor is to be added, followed by a slash (/).
Specifies the number of the port on which the monitor is to be displayed, relative
to its slot for bladed systems. Use
Specifies an interval in (5 or more) seconds. In the case of end-to-end monitor, the
Tx and Rx counts are in the unit of byte when this operand is specified. This
operand is optional; if omitted, this command displays cumulative counts.
0
1
Tx
Rx crc
Tx
Rx crc
0
0
0
0
0
53m
4.9m
0
53m 4.9m 0
53m
4.4m
0
53m 4.4m 0
53m
4.8m
0
53m 4.8m 0
53m
4.6m
0
53m 4.6m 0
53m
5.0m
0
53m 5.0m 0
53m
4.8m
0
53m 4.8m 0
53m
4.5m
0
53m 4.5m 0
52m
4.5m
0
52m 4.5m 0
52m
5.0m
0
52m 5.0m 0
52m
4.5m
0
52m 4.5m 0
52m
4.6m
0
52m 4.6m 0
switchShow
2
3
Tx
Rx crc
Tx
0
0
0
0
0
53m
4.9m
0
53m 4.9m
53m
4.4m
0
53m 4.4m
53m
4.8m
0
53m 4.8m
53m
4.6m
0
53m 4.6m
53m
5.0m
0
53m 5.0m
53m
4.8m
0
53m 4.8m
53m
4.5m
0
53m 4.5m
52m
4.5m
0
52m 4.5m
52m
5.0m
0
52m 5.0m
52m
4.5m
0
52m 4.5m
52m
4.6m
0
52m 4.6m
perfMonitorShow
for a list of valid ports.
4
Rx crc
Tx
Rx
0
0
0
0
0
53m
0
0
53m
0
0
53m
0
0
53m
0
0
53m
0
0
53m
0
0
53m
0
0
52m
0
0
52m
0
0
52m
0
0
52m
0
2
2-411

Advertisement

Table of Contents
loading

Table of Contents