Note: Enter commands in lowercase only; mixed case is for readability.
2
iscsiCfg
To add a new member to an existing DD set (the new DD, iscsidd3, must exist already)
switch:admin> iscsicfg --add ddset -n myddset -d iscsidd3
The operation completed successfully.
To enable a DD set:
switch:admin> iscsicfg --enable ddset -n myddset
This will enable the DDSet specified. Continue [N]: y
To disable a DD set:
switch:admin> iscsicfg --disable ddset
The operation completed successfully.
To display the DD set database in verbose mode:
switch:admin> iscsicfg --show ddset -v
Number of records found: 1
Name:
State/Status:
Num. members:
mynewdd
iqn.2222-23.mytest1
iqn.2343-58.newtest1
iqn.2222-23.mytest3
To delete a DD set:
switch:admin> iscsicfg --delete ddset -n myddset -d mynewdd
The operation completed successfully.
To display the iSCSI-aware switches and their operational states
switch:admin> iscsicfg --show fabric
Switch ID
* 1
Aggregated iSCSI database state for fabric:
Displays switches that are capable of propagating iSCSI data base.
2-304
myddset
Disabled/Defined
1
Switch WWN
10:00:00:60:69:e4:20:1e
Switch State iSNSC
--
Disabled
In Sync
Fabric OS Command Reference Manual