Note: Enter commands in lowercase only; mixed case is for readability.
-nframes count
-ports itemlist
-seed payload_pattern
-width pattern_width
Examples
To perform a loopback port test:
switch:admin> loopporttest -ports 1/0-1/15
Running Loop Port Test .......
Test Complete: "loopporttest" Pass 10 of 10
Duration 0 hr, 0 min & 1 sec (0:0:0:127).
passed.
See Also
camTest, centralMemoryTest, cmemRetentionTest, cmiTest, crossPortTest, itemList,
portLoopbackTest, portRegTest, spinSilk,
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
Specify the number of times (or number of frames per port) to execute this test.
The default value is 10. The maximum value is 2,147,483,647, which is
(2 ^ 31 - 1).
Specify a list of user ports to test. By default, all user ports in the current slot are
tested. Refer to
itemList
for more information on selecting ports.
Specify the seed pattern of the test packets. The data types are:
1
CSPAT
0x7e, 0x7e, 0x7e, 0x7e, ...
2
BYTE_LFSR
0x69, 0x01, 0x02, 0x05, ...
3
CHALF_SQ
0x4a, 0x4a, 0x4a, 0x4a, ...
4
QUAD_NOT
0x00, 0xff, 0x00, 0xff, ...
5
CQTR_SQ
0x78, 0x78, 0x78, 0x78, ...
6
CRPAT
0xbc, 0xbc, 0x23, 0x47, ...
7
RANDOM
0x25, 0x7f, 0x6e, 0x9a, ...
Specify the width of the test pattern. Valid values include:
1
byte (default)
2
word
4
quad
This operand is optional.