Note: Enter commands in lowercase only; mixed case is for readability.
2
snmpConfig
accessControl Configuration Parameters
The ACL check is as follows: there are six ACLs to restrict SNMP get/set/trap operations to hosts under
a host-subnet-area. Host-subnet-area is defined by comparing nonzero IP octets. For example, an ACL
of 192.168.64.0 enables access by any hosts that start with the specified octets. The connecting host is
enabled to set each host-subnet-area to be read-write or read-only. The highest privilege matched out of
six entries is given to the access. The ACL check is turned off when all six entries contain 0.0.0.0. The
default values of all six entries are 0.0.0.0.
Note: When secure mode is enabled, the Access Control List feature is incorporated into the WSNMP
and RSNMP security policies.
mibCapability Configuration Parameters
This mibCapability option a turns on or off certain MIBS and TRAPS.
Note
The
agtCfgDefault
configuration.
If SNMP MIB is disabled, then corresponding traps also are disabled. If any trap group is disabled, then
corresponding individual traps also are disabled.
The FE and SW MIBs are always accessible.
on or off.
FA-MIB
FICON-MIB
HA-MIB
SW-TRAP
FA-TRAP
SW-EXTTRAP
FICON-TRAP
2-624
also resets the SNMP MIB and Trap Capability to default with other SNMP agent
snmpMibCapSet
Specifying yes means the user can access FA-MIB variables with an SNMP
manager. The default value is yes.
Specifying yes means the user can access FICON-MIB variables with an SNMP
manager. The default value is yes.
Specifying yes means the user can access Entity-MIB and HA-MIB variables with
an SNMP manager. The default value is yes.
Specifying yes means the SNMP management application can receive SW-
TRAPS from the switch. The default value is yes. Users can also turn on or off
individual SW Traps. The individual SW traps are swFCPortScn, swEventTrap,
swFabricWatchTrap and swTrackChangesTrap.
Specifying yes means the SNMP management application can receive FA-TRAPS
from the switch. The default value is yes. Users can also turn on or off individual
FA Traps. The individual FA Traps are connUnitStatusChange,
connUnitEventTrap, connUnitSensorStatusChange and
connUnitPortStatusChange.
Specifying yes means user can receive SSN in the SW traps. The default value is
'no'.
Specifying yes means the SNMP management application can receive FICON
traps from the switch. The default value is 'yes'. Users can also turn on or off
individual FICON Traps. The individual FICON Traps are
linkRNIDDeviceRegistration, linkRNIDDeviceDeRegistration,
linkLIRRListenerAdded, linkLIRRListenerRemoved and
linkRLIRFailureIncident.
does not prompt you to turn these MIBs
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01