Brocade Communications Systems A7990A - StorageWorks SAN Director 4/16 Blade Switch Command Reference Manual page 89

Brocade fabric os command reference manual (53-1000240-01, november 2006)
Hide thumbs Also See for A7990A - StorageWorks SAN Director 4/16 Blade Switch:
Table of Contents

Advertisement

Note: Enter commands in lowercase only; mixed case is for readability.
Examples
To test the ASIC central memory:
switch:admin> centralmemorytest -ports 1/0-1/15
Running centralmemorytest ............
Test Complete: centralmemorytest Pass 1 of 1
Duration 0 hr, 0 min & 3 sec (0:0:3:158).
passed.
Diagnostics
When this command detects failure(s), each subtest can report one or more of the following error
messages:
Subtest 2
LCMEM_ERR
LCMRS_ERR
LCMTO_ERR
Subtest 3
CM_NO_BUF
LCMEMTX_ERR
LCMRS_ERR
LCMTO_ERR
Subtest 4
BAD_INT
CM_ERR_PTN
CM_ERR_TYPE
TIMEOUT
Subtest 5
BAD_INT
CM_ERR_PTN
CM_ERR_TYPE
TIMEOUT
Subtest 6
BAD_INT
CM_ERR_PTN
CM_ERR_TYPE
TIMEOUT
Refer to the Fabric OS Message Reference for more information.
See Also
camTest, cmemRetentionTest, cmiTest, crossPortTest, itemList, portLoopbackTest, portRegTest,
spinSilk,
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
sramRetentionTest
centralMemoryTest
2
2-55

Advertisement

Table of Contents
loading