Note: Enter commands in lowercase only; mixed case is for readability.

portFlagsShow

Displays the port status bitmaps for all ports in a switch.
Synopsis
portflagsshow
Description
Use this command to display the following status for a port:
SNMP
Physical
Flags
Note
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands
none
Examples
To display the port status for all ports in the switch:
switch:user> portflagsshow
Slot
Port
SNMP
-----------------------------------------------------
1
0
Online
1
1
Online
1
2
Online
1
3
Online
1
4
Online
1
5
Online
1
6
Online
1
7
Online
1
8
Offline
1
9
Offline
1
10
Offline
1
11
Offline
1
12
Online
1
13
Online
1
14
Online
1
15
Online
4
0
Online
4
1
Online
4
2
Online
4
3
Online
4
4
Offline
4
5
Offline
4
6
Online
4
7
Online
4
8
Online
4
9
Online
4
10
Online
4
11
Online
4
12
Online
4
13
Online
4
14
Online
4
15
Online
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
Displays whether the port is online or offline.
Displays the port physical status. Valid values are In_Sync and No_Light.
Displays whether there is an SFP inserted in the port, whether the port is active,
and the port type.
Physical
Flags
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
No_Light
PRESENT LED
No_Light
PRESENT LED
No_Light
PRESENT LED
No_Light
PRESENT LED
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
No_Light
PRESENT LED
No_Light
PRESENT LED
In_Sync
PRESENT ACTIVE F_PORT L_PORT LOGIN NOELP LED ACCEPT
In_Sync
PRESENT ACTIVE F_PORT L_PORT LOGIN NOELP LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
In_Sync
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT
2
portFlagsShow
2-475