Brocade Communications Systems A7990A - StorageWorks SAN Director 4/16 Blade Switch Command Reference Manual page 449

Brocade fabric os command reference manual (53-1000240-01, november 2006)
Hide thumbs Also See for A7990A - StorageWorks SAN Director 4/16 Blade Switch:
Table of Contents

Advertisement

Note: Enter commands in lowercase only; mixed case is for readability.
TxSIDMsk
TxDIDMsk
RxSIDMsk
RxDIDMsk
Examples
To set the overall mask for end-to-end monitors on a port:
switch:admin> perfsetporteemask 1/6 "00:00:00" "ff:ff:ff" "00:ff:ff" "ff:00:00"
Changing EE mask for this port will cause ALL EE monitors on this port to be
deleted.
continue? (yes, y, no, n): [no] y
The EE mask on port 6 is set and EE Monitors on this port are deleted
See Also
perfAddEEMonitor,
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
Specify the transmitting source ID mask in dd:aa:pp format, with quotation
marks, , where dd is the domain ID mask, aa is the area ID mask, and pp is AL_PA
ID mask. For example, "00:ff:00" uses only the Area ID to trigger the EE monitor.
Specify the following values to turn on or off a specific field:
00
Specifies that the field does not trigger EE monitors.
ff
Specifies that the field does triggers EE monitors.
Specify the transmtting Destination ID mask, in quotation marks, in dd:aa:pp
format.
Specify the recieving Source ID mask, in quotation marks, in dd:aa:pp format.
Specify the destination ID mask, in quotation marks, in dd:aa:pp format.
perfShowEEMonitor
perfSetPortEEMask
2
2-415

Advertisement

Table of Contents
loading

Table of Contents