Note: Enter commands in lowercase only; mixed case is for readability.
Examples
To enable NPIV functionality on a port:
switch:admin> portcfgnpivport 1/3 1
To display NPIV functionality on a port:
switch:admin> portcfgshow
(output from other ports suppressed)
Ports of Slot 1
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed
Trunk Port
Long Distance
VC Link Init
Locked L_Port
Locked G_Port
Disabled E_Port
ISL R_RDY Mode
RSCN Suppressed
Persistent Disable.. .. .. ..
NPIV capability
EX Port
To disable NPIV functionality on a port:
switch:admin> portcfgnpivport 1/3 0
See Also
configure, portCfgDefault,
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
0
1
2
3
4
5
6
AN AN AN AN
AN AN AN AN
ON ON ON ON
ON ON ON ON
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ON
.. .. .. ..
.. .. .. ..
.. .. .. ..
where AN:AutoNegotiate, ..:OFF, ??:INVALID.
LM:L0.5
portCfgShow
portCfgNPIVPort
7
8
9 10 11
12 13 14 15
AN AN AN AN
AN AN AN AN
ON ON ON ON
ON ON ON ON
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
2
2-455