Note: Enter commands in lowercase only; mixed case is for readability.
The Switch Fabric Settings are as follows:
Table 2-3
Field
Domain
R_A_TOV
E_D_TOV
WAN_TOV
MAX_HOPS
Data Field Size
Sequence Level Switching
Disable Device Probing
Suppress Class F Traffic
Switch PID Format
Per-frame Route Priority
Long Distance Fabric
BB Credit
Insistent Domain ID Mode
Descriptions of the switch fabric setting fields are as follows:
Domain
R_A_TOV
E_D_TOV
WAN_TOV
MAX_HOPS
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
Configure Command Fabric Parameters
Type
number
number
number
number
number
number
boolean
boolean
boolean
number
boolean
boolean
number
boolean
The domain number uniquely identifies the switch in a fabric. This value is
automatically assigned by the fabric. The range of valid values varies depending
on the switch model and other system parameter settings.
The resource allocation time out value (R_A_TOV) is displayed in milliseconds.
This variable works with the variable E_D_TOV to determine switch actions
when presented with an error condition.
Allocated circuit resources with detected errors are not released until the time
value has expired. If the condition is resolved prior to the time out, the internal
time-out clock resets and waits for the next error condition.
Error detect time out value (E_D_TOV) is displayed in milliseconds. This timer
is used to flag a potential error condition when an expected response is not
received (an acknowledgment or reply in response to packet receipt, for example)
within the set time limit. If the time for an expected response exceeds the set value,
then an error condition occurs.
Wide area network time out value (WAN_TOV) displays in milliseconds. This
timer is the maximum frame time out value for a WAN, if any, interconnecting the
Fibre Channel islands.
Maximum hops (MAX_HOPS) is an integer that denotes the upper limit on the
number of hops a frame might have to traverse to reach any destination port from
any source port across the fabric.
configure
Default
Range
1
varies
10000
E_D_TOV * 2 to 120000
2000
1000 to R_A_TOV / 2
0
0 to R_A_TOV / 4
7
7 to 19
2112
256 to 2112
0
0 or 1
0
0 or 1
0
0 or 1
1
1 to 2
0
0 or 1
0
0 or 1
16
1 to 27
0
0 or 1
2
2-97