Brocade Communications Systems A7990A - StorageWorks SAN Director 4/16 Blade Switch Command Reference Manual page 673

Brocade fabric os command reference manual (53-1000240-01, november 2006)
Hide thumbs Also See for A7990A - StorageWorks SAN Director 4/16 Blade Switch:
Table of Contents

Advertisement

Note: Enter commands in lowercase only; mixed case is for readability.
The partner port N eventually sends four similar frames, as follows:
5.
Periodically check the following:
a.
b.
c.
The data is not read and checked, as with the
is no CPU intervention besides the periodic checks of the hardware counters.
An example of the data used is as follows:
CSPAT:
BYTE_LFSR:
RANDOM:
RDRAM_PAT:
Because this test includes the media and the fiber cable in its test path, its results, combined with the
results of
are faulty.
Note
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands
This command has the following operands:
-nmegs count
-lb_mode mode
Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
512 bytes of RDRAM_PAT
2112 bytes of BYTE_LFSR
928 bytes of CSPAT
200 bytes of RANDOM
480 bytes of RDRAM_PAT
No port has died.
Each port's frames-transmitted counter is still incrementing.
Each port's statistic error counters is nonzero—ENC_in, CRC_err, TruncFrm, FrmTooLong,
BadEOF, Enc_out, BadOrdSet, DiscC3—until one of the following is met:
The number of million frames requested per port is met.
All ports are eventually marked bad.
You send a keyboard (or button) interrupt to abort.
0x7e, 0x7e, 0x7e, 0x7e, ...
0x69, 0x01, 0x02, 0x05, ...
0x25, 0x7f, 0x6e, 0x9a, ...
0xff, 0x00, 0xff, 0x00, ...
portLoopbackTest
and spinSilk, can be used to determine which components of the switch
Specify the number of million frames to send. The test will progress until the
specified number of frames has been transmitted on each port. The test result
might display that more frames have been transmitted on some ports, but not less.
The default value is 10, so the number of frames sent will be at least 10 million.
Specify the loopback point for the test. By default,
as described earlier; however, for debugging purposes, you can select other
loopback modes, as follows:
1
Port loopback (loopback plugs)
2
External (SERDES) loopback
3
Silkscreen loopback
5
Internal (parallel) loopback
portLoopbackTest
and
crossPortTest
spinSilk
2
spinSilk
commands. There
uses loopback plugs
2-639