APPENDIX E: Type of proximity keys that can be read by IPerCom devices with access control function
contains a table with a list of devices that integrate a key reader and the different types of proximity keys
that can be read by these devices.
To speed up the insertion of the key code in the configurator page, an automatic reading device (Universal
Encoder) of the code is available for keys with Mifare, Mifare Plus technology and dual technology.
Simply connect the Universal Encoder device to a USB port on your computer (using the supplied cable): in
this way the device is powered and the LED on the front panel switch from green (about 1s) to steady red.
Now, after opening any text editor on your PC (Notepad for example), simply bring the key close to the
white recess on the front of the device: the key code is immediately displayed on the text editor and can
then be copied and pasted in the relevant field of the resident or non-resident page you are adding to the
configuration.
Residents may also be associated with 2Voice apartments as described above. These residents will
appear in the address books of the IPerCom Call Modules and will have access to the respective gates
within their competence and not via Proximity Keys or Door Codes which may have a time limit or not.
After adding for example 2 users for the "Apartment 01010101", if you go to that topological node you will
see the updated list of residents in the context menu.
The buttons in the columns "Edit" and "Delete" allow you to modify the data or delete each user created,
respectively (through confirmation pop-up).